logo
products
PRODUCTS DETAILS
Home > Products >
Industrial Glycol Chiller

Industrial Glycol Chiller

MOQ: 1
Price: USD
Standard Packaging: Woodern box
Delivery Period: 25 days
Payment Method: T/T,L/C
Supply Capacity: 300pcs/month
Detail Information
Place of Origin
China
Brand Name
Bosikar
Certification
CE
Model Number
BSKS-100A
Chiller Type:
Water-Cooled Chiller
Compressor Type:
Screw Compressor Or Piston Compressor
Compressor Brand:
Hanbell, Bitzer
Refrigerant:
R404a
Evaporator:
Shell And Tube
Condenser:
Shell And Tube
Voltage:
380V / 50Hz (Customizable)
Warranty:
15 Months
After-sales Service Provided:
Engineers Available To Service Overseas, Online Support, Video Technical Support
Application:
Industrial Process Cooling, Injection Machine Cooling, Extruder Machine Cooling, Chemical Application
Product Description

 Industrial Sub-Zero Cooling Solution by BOSIKAR


Product Overview

The BOSIKAR Water-Cooled Glycol Chiller is a high-performance industrial refrigeration system designed for stable sub-zero cooling using a glycol–water mixture.
By circulating glycol, it effectively lowers the freezing point of the coolant, ensuring safe, reliable, and continuous operation for industrial processes requiring low-temperature control.

Water-cooled chillers use external water from a cooling tower to remove heat from the condenser, providing higher energy efficiency and stable performance even in high ambient temperatures.



Advantages of Water-Cooled Glycol Chillers

  • Higher efficiency than air-cooled chillers (higher COP)

  • Stable cooling performance under high ambient temperature conditions

  • Low noise operation, ideal for indoor installations

  • Suitable for medium to large cooling capacity industrial applications

  • Integrated glycol system for sub-zero temperature control



Wide Low-Temperature Operating Range

  • Chilled fluid temperature range: 0°C to -40°C
  • High temperature stability for continuous operation
  • Optimized refrigeration system for low-temperature performance

The chilled glycol solution is circulated through the process equipment via a high-efficiency chiller pump, ensuring uniform heat removal and consistent cooling performance.



System Features

Water-Cooled Condenser

  • Uses water from an external cooling tower
  • Stable heat rejection under continuous operation
  • Minimizes compressor load for higher efficiency
  • Supports large industrial cooling systems

Glycol Anti-Freezing System

  • Glycol–water mixture lowers freezing point

  • Protects evaporator, pumps, and piping in sub-zero applications

  • Ensures safe and reliable long-term operation



Low Temperature Glycol Chiller – Technical Specification

Item

Specification

Model

BSK-100WDL

Chilled Fluid

Glycol–Water Mixture

Cooling Capacity

189kW at outlet -10°C

Fluid Temperature Range

0°C to -40°C

Temperature Stability

±2°C

Refrigerant

R404A (optional)

Compressor Type

Screw (industrial grade)

Condenser Type

Water-cooled shell and tube

Evaporator Flow Rate

48m³/h

Condenser Flow Rate

40 m³/h

Ambient Temperature Range

-15°C to 50°C

Power Supply

380–415V / 50Hz / 3 Phase (customizable)

Control System

PLC controller, real-time monitoring

Protection Features

High/Low pressure, anti-freezing, overload, phase loss, phase sequence

Noise Level

≤ 68 dB

Dimensions (L×W×H)

3200 × 1150 × 2200 mm

Weight

2200 kg

Applications

CNC machine tools, beverage filling, spindle cooling, chemical reaction systems, grinding/milling machines, welding/cutting equipment, laboratory and process cooling

Notes

  • Specifications are for reference; customization available based on site requirements and glycol concentration.
  • Optional water-cooled version available for higher efficiency and quieter operation.
  • Flow rate, voltage, and refrigerant type can be adjusted according to customer demand.




Reliable Industrial Configuration

High-Quality Core Components

  • Industrial-grade compressor (scroll or screw, optional)
  • High-efficiency evaporator designed for glycol media
  • Optimized refrigeration circuit for low-temperature stability
  • Designed for 24/7 continuous industrial operation


Typical Applications

  • BOSIKAR industrial glycol chillers are widely used in:
  • Beverage filling and food processing lines
  • Grinding and milling machines
  • Chemical reaction systems
  • Welding machines
  • Laser cutting and cutting machines
  • Pharmaceutical, laboratory, and process cooling applications

The system supports temperature adjustment up to 40°C below zero, meeting the requirements of demanding industrial environments.



Air-Cooled vs Water-Cooled Chiller: Quick Comparison

 

Feature

Air-Cooled Chiller

Water-Cooled Chiller

Cooling Medium

Air

Water

Cooling Tower

Not required

Required

Energy Efficiency

Moderate

High

Water Consumption

None

Required

Installation Cost

Lower

Higher

Maintenance

Simple

More complex

Suitable Capacity

Small–Medium

Medium–Large



Application Recommendations

Choose an Air-Cooled Chiller if:

  • Water resources are limited or restricted

  • Installation space is flexible (outdoor installation)

  • Initial investment budget is limited

  • Cooling capacity requirement is small to medium

Choose a Water-Cooled Chiller if:

  • High energy efficiency is a priority

  • Ambient temperature is high (hot climate regions)

  • Large cooling capacity or 24/7 continuous operation is required

  • Stable and quiet operation is important


 

Recommended Products
products
PRODUCTS DETAILS
Industrial Glycol Chiller
MOQ: 1
Price: USD
Standard Packaging: Woodern box
Delivery Period: 25 days
Payment Method: T/T,L/C
Supply Capacity: 300pcs/month
Detail Information
Place of Origin
China
Brand Name
Bosikar
Certification
CE
Model Number
BSKS-100A
Chiller Type:
Water-Cooled Chiller
Compressor Type:
Screw Compressor Or Piston Compressor
Compressor Brand:
Hanbell, Bitzer
Refrigerant:
R404a
Evaporator:
Shell And Tube
Condenser:
Shell And Tube
Voltage:
380V / 50Hz (Customizable)
Warranty:
15 Months
After-sales Service Provided:
Engineers Available To Service Overseas, Online Support, Video Technical Support
Application:
Industrial Process Cooling, Injection Machine Cooling, Extruder Machine Cooling, Chemical Application
Minimum Order Quantity:
1
Price:
USD
Packaging Details:
Woodern box
Delivery Time:
25 days
Payment Terms:
T/T,L/C
Supply Ability:
300pcs/month
Product Description

 Industrial Sub-Zero Cooling Solution by BOSIKAR


Product Overview

The BOSIKAR Water-Cooled Glycol Chiller is a high-performance industrial refrigeration system designed for stable sub-zero cooling using a glycol–water mixture.
By circulating glycol, it effectively lowers the freezing point of the coolant, ensuring safe, reliable, and continuous operation for industrial processes requiring low-temperature control.

Water-cooled chillers use external water from a cooling tower to remove heat from the condenser, providing higher energy efficiency and stable performance even in high ambient temperatures.



Advantages of Water-Cooled Glycol Chillers

  • Higher efficiency than air-cooled chillers (higher COP)

  • Stable cooling performance under high ambient temperature conditions

  • Low noise operation, ideal for indoor installations

  • Suitable for medium to large cooling capacity industrial applications

  • Integrated glycol system for sub-zero temperature control



Wide Low-Temperature Operating Range

  • Chilled fluid temperature range: 0°C to -40°C
  • High temperature stability for continuous operation
  • Optimized refrigeration system for low-temperature performance

The chilled glycol solution is circulated through the process equipment via a high-efficiency chiller pump, ensuring uniform heat removal and consistent cooling performance.



System Features

Water-Cooled Condenser

  • Uses water from an external cooling tower
  • Stable heat rejection under continuous operation
  • Minimizes compressor load for higher efficiency
  • Supports large industrial cooling systems

Glycol Anti-Freezing System

  • Glycol–water mixture lowers freezing point

  • Protects evaporator, pumps, and piping in sub-zero applications

  • Ensures safe and reliable long-term operation



Low Temperature Glycol Chiller – Technical Specification

Item

Specification

Model

BSK-100WDL

Chilled Fluid

Glycol–Water Mixture

Cooling Capacity

189kW at outlet -10°C

Fluid Temperature Range

0°C to -40°C

Temperature Stability

±2°C

Refrigerant

R404A (optional)

Compressor Type

Screw (industrial grade)

Condenser Type

Water-cooled shell and tube

Evaporator Flow Rate

48m³/h

Condenser Flow Rate

40 m³/h

Ambient Temperature Range

-15°C to 50°C

Power Supply

380–415V / 50Hz / 3 Phase (customizable)

Control System

PLC controller, real-time monitoring

Protection Features

High/Low pressure, anti-freezing, overload, phase loss, phase sequence

Noise Level

≤ 68 dB

Dimensions (L×W×H)

3200 × 1150 × 2200 mm

Weight

2200 kg

Applications

CNC machine tools, beverage filling, spindle cooling, chemical reaction systems, grinding/milling machines, welding/cutting equipment, laboratory and process cooling

Notes

  • Specifications are for reference; customization available based on site requirements and glycol concentration.
  • Optional water-cooled version available for higher efficiency and quieter operation.
  • Flow rate, voltage, and refrigerant type can be adjusted according to customer demand.




Reliable Industrial Configuration

High-Quality Core Components

  • Industrial-grade compressor (scroll or screw, optional)
  • High-efficiency evaporator designed for glycol media
  • Optimized refrigeration circuit for low-temperature stability
  • Designed for 24/7 continuous industrial operation


Typical Applications

  • BOSIKAR industrial glycol chillers are widely used in:
  • Beverage filling and food processing lines
  • Grinding and milling machines
  • Chemical reaction systems
  • Welding machines
  • Laser cutting and cutting machines
  • Pharmaceutical, laboratory, and process cooling applications

The system supports temperature adjustment up to 40°C below zero, meeting the requirements of demanding industrial environments.



Air-Cooled vs Water-Cooled Chiller: Quick Comparison

 

Feature

Air-Cooled Chiller

Water-Cooled Chiller

Cooling Medium

Air

Water

Cooling Tower

Not required

Required

Energy Efficiency

Moderate

High

Water Consumption

None

Required

Installation Cost

Lower

Higher

Maintenance

Simple

More complex

Suitable Capacity

Small–Medium

Medium–Large



Application Recommendations

Choose an Air-Cooled Chiller if:

  • Water resources are limited or restricted

  • Installation space is flexible (outdoor installation)

  • Initial investment budget is limited

  • Cooling capacity requirement is small to medium

Choose a Water-Cooled Chiller if:

  • High energy efficiency is a priority

  • Ambient temperature is high (hot climate regions)

  • Large cooling capacity or 24/7 continuous operation is required

  • Stable and quiet operation is important